City Line ConstructionAirKrete Insulation
Air Krete Is An All Green Insulation... High R Value... Fire Proof... Mold Resistant... Pest Resistant... Non Allergenic... Zero Shrinkage ... Also Acts As A Sound Barrier....

City Line Construction LTD
PO Box 36523, 5970 Mullan Way
Edmonton, Alberata T6R 0S9
780.757.7725


TESTING

air krete® has obtained approval for use in every state and local jurisdiction that acceptance has been requested.

Hardwood Plywood Manufacturers Association
Report on surface burning characteristics determined by ASTM-E 84 Twenty-five foot tunnel furnace test method.

The normal 10 minute test was extended to 30 minutes with the following results:
Flamespread Factor: 0
Fuel Contributed Factor: 0
Smoke Density Factor: 0

Dynatech
The apparent thermal resistance of a specimen of a cementitious foam insulation material density:
2.07 lbs. per cubic foot @ 24C (75F)
K factor = .257 per 1 inch thickness
R factor = 3.9 per 1 inch thickness

Twin City Testing Corporation Report of shrinkage test conducted according to ASTM: C951, Par. 8.5 results:
Shrinkage, Inches: 0.00
Percent Shrinkage: 0.00

Consumer Product Safety Commission
Result of sample analysis report on air krete® : Totals Formaldehyde: None detected Formaldehyde in air: Non detected

Penniman & Brown, Inc.
Chemists, Engineers, Inspectors - Baltimore, Maryland, Analytical Division
Report of analysis sample of reacted foam insulation identified as air krete® , was qualitatively checked for formaldehyde:
No evidence of formaldehyde was found.

Hardwood Plywood Manufacturers Association Report on smoke density characteristics determined by NBS-Aminco Smoke Density Chamber. These test results demonstrate:
air krete® is non-toxic.

A Microbial Resistance Evaluation of Indoor Materials

air krete® Insulation Sample

Executive Summary / Project Description
Air Quality Sciences, Inc. (AQS) is pleased to present the results of its microbial resistance evaluation of air krete's indoor material identified as “ air krete® Insulation Sample”. AQS conducted this study using a microbial test protocol following the requirements of ASTM Guideline D 6329-98 (1). This ASTM method is established to study indoor materials for their ability to support mold growth. Testing of the indoor material was conducted using static environmental chambers operating at 75% humidity
(considered a *high normal” for indoor commercial spaces) and 95% humidity (considered an extreme moisture condition within buildings). air krete's indoor material was inoculated with two representative indoor molds, Stachvbotrvs chartarum and Eurotium amstelodami, and growth rates were measured over a three-week period as the materials were exposed in the two humidity environments. Mold growth is considered significant if it exceeds 20% of the initial baseline levels. Test methodology
and results are given in the attached summary reports.

Results
Results show that the “ air krete® Insulation Sample” was resistant to mold growth at both 75% and 95% relative humidities. Neither molds were found to amplify in the materials at either humidity.

 

 
Chrysler Building in NY City National Audubon Society Air Krete was installed in Al Gore's Home Bio Shere

Air Krete can be installed install buildings like the top of the Chrysler Building iin NYC.

Air Krete can be installed in existing stuctures.National Audubon in NY City
Old Schermerhorn Building

Air Krete can be installed in any existing or new building stuctures. Al Gore's Home, TN

Air Krete can be installed in commercial & industrial structures.
Biosphere 2 Visitors Center, AZ

©2010 AirKrete Inc.  All Rights Reserved.